Permit: T10CM03492

Parcel: 10707003H


Addresses:

2727 N FAIRVIEW AV

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
04/05/2011 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*ADD HANGERS AS REQ'D. OK TO COVER WALLS STOI
03/30/2011 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1) ABS TO BE SUPPORTED AT EACH CHANGE OF DIRECTION OR ELEVATION AND AT THE END OF BRANCHES, THEN NO MORE THAN 4' BETWEEN HANGERS
2) USE APPROVED HANGERS
3) ISOLATE ABS FROM METAL STUD
4) MID STORY GUIDE FOR VERTICAL PIPE
5) INSULATION PER MANUFACTURERS RECOMMENDATION