Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T10CM03491
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/14/2011 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 07/13/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) TERMINATE EXTERIOR CLEANOUTS 2) PROVIDE BUG SCREEN AT UNDERGROUND GAS VENT TERMINATION 3) COMPLETE PIPING TO EXTERIOR HEATERS 4) PROTECT VENT THRU ROOF FROM SUN EXPOSURE 5) COMPLETE ALL INSTALLS FOR PLUMBING ITEMS 6) PROVIDE APPROVED TRAP ARM FOR HAND SINK AT TEA AREA 7) PROVIDE APPROVED ICE BIN DRAINS WITH 1" AIR GAPS AT TERMINATIONS FOR ALL INDIRECT DISCHARGE REQUIRING IT 8) ALL GAS APPLIANCES ON WHEELS REQUIRE SAFETY CABLES 9) COMPLETE CORRECT DRAINAGE AT EMPLOYEE RESTROOM HAND SINK 10) ALL FIXTURES TO BE WATER TIGHT 11) PROVIDE STERILIZATION AND BACTERIA REPORTS WITH BACKFLOW CERTS 12) JANITOR SINK VACUUM BREAKER FAUCETS NOT COMPLIANT WITH VALVES DOWNSTREAM |