Permit: T10CM03478

Parcel: 11717023E


Addresses:

88 E BROADWAY BL

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
11/10/2011 PLUMBING - INTERMEDIATE Approved
11/03/2011 PLUMBING - INTERMEDIATE Partial Approval NEED TO SEE TEST ON GARAGE SUMPS
10/11/2011 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
09/29/2011 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) DWV, DOMESTIC WATER AHD RO TO COFFEE 273 WITH WATER HEATER IN MECH 1 208 OK
09/13/2011 PLUMBING - INTERMEDIATE Partial Approval LEVEL 2 - DOMESTIC AND RO ABOVE CEILING. STILL NEED TO SEE W.H. TIE IN @ MECH ROOM
08/23/2011 PLUMBING - INTERMEDIATE Denied 3 COMPARTMENT SINK IN PANTRY 261 REQUIRES DIRECT CONNECTION TO DRAINS AS PER APPROVED PLANS.
08/23/2011 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
L-9 FUTURE 3" W/CONNECTON TO STACK 8-OK
RM.959 SINK DWV AND WATERS OK
L-3 RM 340 P-15 W/ TEST OK
L-2 RM 273 OFFICE WALLS ONLY.
PANTRY REVENT OF FS OK. STILL NEED CORRECT 3 COMP SINK DRAIN. HARD LID IN HALL AT STR 6 OK.
HOW WILL YOU SEAL THE CONECTION BETWEEN TILED RAISED FLOOR AND YOUR FLOOR SINKS? A FLANGED FIXTURE WOULD BE APPROPRIATE FOR A WATER SISAL CONNECTION. HAVE YOU INSTALLED THE WRONG SINK?
08/18/2011 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) BR #256 DWV, DOMESTIC AND ? WATER INWALLS ONLY OK. RECALL FOR COMPLETION ON WASTE AND VENT
2) BR #246 IN WALL OK, RECALL FOR WASTE INSPECTION
08/15/2011 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) BR SINK PIPING IN WALLS ROOM #371 TEST OK
2) ROOM #351 DWV TEST IN WALLS OK
3) LEVEL 9 ROOM 932 FUTURE 3" DWV BELOW FLOOR OK
4) ROOM #959 SINK IN WALLS AND WATER PIPING OVERHEAD TO TIE IN
08/01/2011 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) DWV LEVEL 9 BR SINK IN WALLS AND ABOVE CEILING OK, INSTALL MISSING SAFETY PLATES
2) DOMESTIC AND RO PIPING LOOKS GOOD, NOT YET UNDER TEST (EAST BREAK ROOMS)
07/29/2011 PLUMBING - INTERMEDIATE Partial Approval LEVEL 9 WEST DWV AND POTABLE AIR TEST 5 PSI OK. OK TO COVER WALLS
07/22/2011 PLUMBING - INTERMEDIATE Partial Approval LVLS 4 - 8 1/2" RO & CW FROM EAST MECH TO BREAK ROOM
07/20/2011 PLUMBING - INTERMEDIATE Partial Approval NEED TEST ON VENT EAST LVL 9 (FUTURE STUB OUT)
07/15/2011 PLUMBING - INTERMEDIATE Partial Approval RELOCATE STUBOUTS ON LEVEL 4 OK
07/13/2011 PLUMBING - INTERMEDIATE Partial Approval RELOCATION OF 3" DRAIN STUB AT RESTROOM CORE LEVELS 5-9 OK. 4 NOT READY
06/29/2011 PLUMBING - INTERMEDIATE Partial Approval RELOCATION OF 3" STUB OUT ON DWV ABOVE CIELING LEVEL 6 & 9 OK. NEED TO UNCOVER 5 AND REWORK 7.
04/22/2011 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
04/18/2011 PLUMBING - INTERMEDIATE Not ready for Inspection 4/18/11 NOTHING READY PER ROB

4/20/11 CPVC IN WALL, LEVELS 4-8, WEST BR SINK, TEST OK. SECURE PIPING AS PREVIOUSLY REQUESTED.
DOMESTIC WATER IN WALL AT BR SINK, LEVEL 8 TEST OK.
INSULATE DOMESTIC HW, ALL LEVELS
04/14/2011 PLUMBING - INTERMEDIATE Not ready for Inspection DO NOT TEST CPVC WITH AIR, TEST HYDROSTATICALLY, BLEED ALL AIR FROM LINE.
PUTTING AN INSPECTORS SAFETY AT RISK WILL INCUR FEES.
SECURE CPVC RO PIPING
04/07/2011 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) FAMILY RR #444 AND BR 463 SINK; DWV AND DOMESTIC WATER TEST OK
04/06/2011 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*