Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - PROGRESS
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/24/2012 | ELECTRIC - PROGRESS | Approved | ||
| 11/18/2011 | ELECTRIC - PROGRESS | Partial Approval | OK H1W, EHLW, P1WB, P1WA, SB1W, EHLW,EPFCC, SB1E, HL1E, EHLE, H1E, HL1E, UPS1E, PCP, CPB, CPA, HCP 1) GROUND LV RACEWAYS ON STAIRS 2) PANEL DIRECTORIES NOT CORRECT 3) PROTECT CONDUCTORS AT DISCONNECTS 4) SWITCH DIVIDERS 5) FINISH REDUCING WASHERS & BOND BUSHINGS @ OSMOSIS EQUIPMENT |
|
| 11/17/2011 | ELECTRIC - PROGRESS | Not ready for Inspection | IVRS - Inspection :* | |
| 11/16/2011 | ELECTRIC - PROGRESS | Not ready for Inspection | IVRS - Inspection :* 1) DISCUSSED SA LIGHTS |
|
| 11/15/2011 | ELECTRIC - PROGRESS | Not ready for Inspection | IVRS - Inspection :* | |
| 11/14/2011 | ELECTRIC - PROGRESS | Not ready for Inspection | IVRS - Inspection :* 1) DISCUSED SCHEDULING |
|
| 11/10/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 11/10/2011 | ELECTRIC - PROGRESS | Partial Approval | ||
| 11/09/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* 1) OK FLOOR BOXES MAIN LOBBY 2) OK BRANCH CIRCUITS PB2, PSBB3, PSPFCC 3) OK EV CHARGER 2 ON B-2 AND 1 ON B-1 4) PROPERLY INSTALL LOCK NUT IN GUTTER ON WEST STAIR WELL AT B-1 5) GUTTER COMING OFF WALL IN FCC ROOM |
|
| 11/08/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* 1) OK BRANCH CIRCUITS SB3W, UPS3W, H3W, HL3W, UPS3B, SB3E, PSBCP, HSBCP AND HDC 2) OK BOLLARD LIGHTS ROOF: 1) BOXES UP OVER 12" NEED SUPPORT 2) MISSING COVERS VDV RACEWAYS AND BOXES 3) LOBBY ELEVATOR ROOM NOT WORKING 3RD FLOOR: 1) KO SEAL BOX IN WALL MECHANICAL ROOM WEST 2) LIGHT BOX OPEN ELECTRIC ROOM 3 WEST 3) AT FILTERS/OSMOSIS EQUIPMENT REDUCING WASHER NOT CORRECTLY INSTALLED, NEED BOND BUSHINGS, LABEL DISCONNECTS AND CONTACTORS 110.3 & 250.97 4) MISSING RECEPT COVER |
|
| 11/07/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* 1) OK LIGHTS NORTH HALL AND ELECTRIC COVES 2ND FLOOR 2) OK LIGHTS IN BUSS DUCT SHAFT ROOM 2ND FLOOR 3) OK 2 EV CHARGERS 2ND FLOOR PARKING 4) OK MAINTENANCE ROOM LIGHTS 3RD FLOOR 5) BOXES MORE THAN 1/4" 314.20 OR 1/8" 314.21 AT LOBBY MARBLE AND IN MECHANICAL ROOMS INSPECTION FOR #T10CM01795 FROM R. HOLLANDER: 1) PROTECT CONDUCTORS-LARGE JUNCTION BOX 9TH FLOOR 2) FINISH VERTICAL SUPPORTS HSBR FEED 300.19 3) CAP UNUSED RACEWAYS 4) PANEL DIRECTORIES 408.4 NOTE: ELECTRICAL INSPECTIONS AND CORRECTIONS PERFORMED AND APPROVED FOR PERMIT #T10CM01795 WERE DONE WITHIN MY LIMITED ROLE AND TO THE BEST OF MY ABILITY TO ENFORCE CODE COMPLIANCE IN ACCORDANCE WITH CURRENTLY ADOPTED NEC AND ALL APPLICABLE CITY OF TUCSON AMENDMENTS |
|
| 11/04/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* 1) OK LIGHTING TRANSFORMER VAULT ROOM, LOBBY WALL, WALL PACKS, LIGHTING CONTROLS 4-9, FIRE PUMP ROOM POWER, AUDITORIUM CONTROL PANEL FOR ROOM DIVIDERS AND SERVER DOOR |
|
| 11/02/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* 1) PROTECT CONDUCTORS-LARGE JUNCTION BOX 9TH FLOOR 2) PANEL DIRECTORIES 408.4 3) MISSING GUTTER COVER SCREWS |
|
| 11/01/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* 1) VERIFY LISTING FOR LIFT ASSEMBLY IN MAIN FLOOR OPEN AREA 2) PROTECT SEAL TITE FROM SHARP METAL EDGES AT EXHAUST FAN 4TH FLOOR ROOF 3) FINISH ELECTRIC ROOMS 4) BOXES MORE THAN 1/4" AT BARRIER 314.20 |
|
| 10/28/2011 | ELECTRIC - PROGRESS | Not ready for Inspection | IVRS - Inspection :* | |
| 10/27/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* 1) MISSING COVERS ON BOXES AND CONDUCTORS (VDV) 2) WHO IS LABELING VFD'S ? |
|
| 10/26/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* 1) FINISH EXHAUST FANS ROOF OF GARAGE 2) FINISH LIGHTING ROOF OF GARAGE 3) BOXES ON BLDG PATIO OF 4TH FLOOR 314.20 4) FINISH WORK BOXES FIRE PUMP ROOM |
|
| 10/25/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* 1) OK AUDITORIUM CONTROL PANEL FOR PARTITION WALLS 2) NEED ARC SHIELDS IN CABINETS 314.20 3) CORDS NOT ALLOWED ABOVE CEILING TILES 400.7 & 8 |
|
| 10/19/2011 | ELECTRIC - PROGRESS | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 10/18/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* 1) FINISH LIGHTING RELAYS 2) NEED ACCESS 5C 3) HANDLE TIE 605.7 4) PANEL DIRECTORIES 408.4 |
|
| 10/17/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 10/13/2011 | ELECTRIC - PROGRESS | Not ready for Inspection | IVRS - Inspection :* 1) GENERAL WALK THRU |
|
| 10/07/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 10/06/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 09/30/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 09/29/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 09/28/2011 | ELECTRIC - PROGRESS | Not ready for Inspection | IVRS - Inspection :* | |
| 09/27/2011 | ELECTRIC - PROGRESS | Denied | IVRS - Inspection : See detailed listing on site.| 999* 5TH FLOOR: 1) BOXES CUT ON ROUNDS 314.2 2) PROTECT CONDUCTORS FROM SHARP METAL EDGES 3) FINISH TV RECEPTS AND UTILIZE GROUND SCREW FOR ENCLOSURE 4) SECURE FLOOR BOXES 5) MISSING SWITCHES AND PLATE COVERS FOR ALL DEVICES 6) BOXES MORE THAN 1/4" 314.20 7) UNMADE UP LIGHT BOXES 8) MISSING EXIT SIGNS ROOM 545 9) MISSING JUNCTION BOX COVERS AND KO'S 10) NEED SEPERATION OF DEVICES OVER 300V TO GROUND 404.8 |
|
| 09/26/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 09/23/2011 | ELECTRIC - PROGRESS | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 09/22/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* 1) OK PANEL EPFCC 2) OK POWER FOR AHU1.1 |
|
| 09/21/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* 1) OK LIGHTS ROOM FCC |
|
| 09/20/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* 1) OK BRANCH CIRCUITS P4EA,P4EB,P4WA,P4WB 2) VERIFY CABLE VOLTAGE RATING FOR VDV CABLING IN GUTTER |
|
| 09/19/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 09/16/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 09/15/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 09/14/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 09/13/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 09/12/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 09/09/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 09/08/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 09/07/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 09/06/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 08/26/2011 | ELECTRIC - PROGRESS | Partial Approval | ||
| 08/25/2011 | ELECTRIC - PROGRESS | Not ready for Inspection | IVRS - Inspection :* | |
| 08/24/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* 1) SUPPORT VAV CABELING ROOMS 958, 959 2) NEED ACCESS TO JUNCTION BOXES 9TH FLOOR LIDS 1) NEED DISCONNECTING MEANS SCREEN & PARTFLOW MOTORS (AS PLANS) ROOM 241 2) MEET WITH DAN COSTRUST - 604.6 (E) & 348.30 (A) WILL APPLY. SECURE WITHIN 12" PDMI BOXES, 6' W------TO BOXES IN FLOOR SECURING TO LESS IS OK 3) PROTECT VDV CASLING FROM SHARP METAL EDGES. |
|
| 08/23/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 08/23/2011 | ELECTRIC - PROGRESS | Partial Approval | MEET WITH GARRETT OF RYAN AND PARSONS ELECTRIC TO DISCUSS 300.11 AND APPLICATION CODE | |
| 08/22/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 08/19/2011 | ELECTRIC - PROGRESS | Partial Approval | ||
| 08/18/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 08/17/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 08/16/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 08/15/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 08/11/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 08/10/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 08/09/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 08/08/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 08/05/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 08/04/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 08/02/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 08/01/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 07/29/2011 | ELECTRIC - PROGRESS | Partial Approval | LVLS 7,8,9 UNDER FLOOR INTERMEDIATE OK | |
| 07/27/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 07/26/2011 | ELECTRIC - PROGRESS | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 07/25/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 07/22/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 07/21/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 07/20/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 07/19/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 07/18/2011 | ELECTRIC - PROGRESS | Not ready for Inspection | IVRS - Inspection :* GENERAL WALK THROUGH | |
| 07/14/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 07/13/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 07/12/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 07/11/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 07/08/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 07/07/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 07/06/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 07/01/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 06/30/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 06/29/2011 | ELECTRIC - PROGRESS | Not ready for Inspection | IVRS - Inspection :* | |
| 06/28/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 06/27/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 06/24/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* 1) OK PATIO ON 4TH FLOOR WALLS-REDO |
|
| 06/23/2011 | ELECTRIC - PROGRESS | Not ready for Inspection | IVRS - Inspection :* | |
| 06/22/2011 | ELECTRIC - PROGRESS | Not ready for Inspection | IVRS - Inspection :* | |
| 06/21/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 06/16/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* 1) OK HARD LID 8 WEST |
|
| 06/15/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 06/14/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 06/13/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 06/08/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 06/07/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 06/06/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* OK 9TH FLOOR CONDUIT PLUG + PLAY EAST "D" 1. SUPPORT VDV CABLEING 725.8, 760.24, 770.24, 800.24 2. MEET WITH HECTOR ACC. DISCUSSED WORK BY HIS COMPANY A. CONTROL PANELS CANNOT USE SHEET METAL THREAD SCREWS 250.8 B. SUPPORT CONDUIT ENTERING EAST SHAFT IN ROOF C. TIGHTENING HOUSE FITTINGS |
|
| 06/03/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 06/02/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 06/01/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 06/01/2011 | ELECTRIC - PROGRESS | Partial Approval | ||
| 05/31/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* 1) WALLS COVERED WITHOUT INSPECTION 635, 637 2) MOVE SUPPORT 629 |
|
| 05/25/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* 1) OK SWITCH RELOCATIONS 525, 527, 534, 535, 538, 543, 625, 627, 634, 638, 639 & 643 2) OK PLUG AND PLAY POWER BOXES AND FLEX RUNS 8TH FLOOR EAST OF "D" 3) OK TO 8-10, 18, 19, 20 & 22 4) DOOR TO OPEN 90 DEGREE DISCONNECT TO 7-7 |
|
| 05/23/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 05/20/2011 | ELECTRIC - PROGRESS | Not ready for Inspection | IVRS - Inspection :* 1) NO WORK |
|
| 05/19/2011 | ELECTRIC - PROGRESS | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* |
|
| 05/18/2011 | ELECTRIC - PROGRESS | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 05/17/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 05/16/2011 | ELECTRIC - PROGRESS | Not ready for Inspection | IVRS - Inspection :* | |
| 05/13/2011 | ELECTRIC - PROGRESS | Partial Approval | ||
| 05/11/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 05/10/2011 | ELECTRIC - PROGRESS | Partial Approval | UNDER FLOOR LEVEL 6 EAST OF LINE D OK | |
| 05/09/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 05/06/2011 | ELECTRIC - PROGRESS | Not ready for Inspection | IVRS - Inspection :* | |
| 05/05/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 05/04/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 05/03/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 05/02/2011 | ELECTRIC - PROGRESS | Not ready for Inspection | IVRS - Inspection :* NO WORK | |
| 04/29/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 04/28/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 04/27/2011 | ELECTRIC - PROGRESS | Not ready for Inspection | IVRS - Inspection :* | |
| 04/26/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 04/25/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 04/22/2011 | ELECTRIC - PROGRESS | Partial Approval | DATA AND RIGID POWER RUNS EAST OF LINE D UNDER FLOOR OK. POWER LINES FOR "PLUG & PLAY" NOT INSTALLED. MAKEUP STILL MISSING. | |
| 04/21/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 04/20/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* WAITING ON ANSWERS FOR COLD CATHODE LIGHTING |
|
| 04/19/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 04/18/2011 | ELECTRIC - PROGRESS | Not ready for Inspection | IVRS - Inspection :* | |
| 04/14/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 04/13/2011 | ELECTRIC - PROGRESS | Not ready for Inspection | IVRS - Inspection :* | |
| 04/12/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 04/11/2011 | ELECTRIC - PROGRESS | Not ready for Inspection | IVRS - Inspection :* | |
| 04/08/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 04/07/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* 5TH FLOOR: 1) FILL UNUSED OPENINGS IN BOXES 2) WAITING FOR FLOOR SUPPORT LEGS TO SUPPORT VDV CABLING PER 725.8 AND 800.24 |
|
| 04/06/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 04/05/2011 | ELECTRIC - PROGRESS | Not ready for Inspection | IVRS - Inspection :* | |
| 04/04/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 04/01/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 03/31/2011 | ELECTRIC - PROGRESS | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO WORK PROGRESS 2) TIGHTEN LOOSE FITTINGS 3) NO MORE THAN 360 DEGREE IN CONDUIT RUNS |
|
| 03/30/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 03/29/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* | |
| 03/25/2011 | ELECTRIC - PROGRESS | Partial Approval | IVRS - Inspection :* |