Permit: T10CM03478

Parcel: 11717023E


Addresses:

88 E BROADWAY BL

Inspection Status: Approved

Inspection History: FIREWALL/FIREBARRIER/FIRESTOP

Date Description Inspector Results Comments
11/10/2011 FIREWALL/FIREBARRIER/FIRESTOP Approved
11/03/2011 FIREWALL/FIREBARRIER/FIRESTOP Partial Approval
10/25/2011 FIREWALL/FIREBARRIER/FIRESTOP Partial Approval
10/24/2011 FIREWALL/FIREBARRIER/FIRESTOP Partial Approval
10/03/2011 FIREWALL/FIREBARRIER/FIRESTOP Partial Approval
09/13/2011 FIREWALL/FIREBARRIER/FIRESTOP Partial Approval
08/26/2011 FIREWALL/FIREBARRIER/FIRESTOP Partial Approval
08/23/2011 FIREWALL/FIREBARRIER/FIRESTOP Partial Approval
08/17/2011 FIREWALL/FIREBARRIER/FIRESTOP Partial Approval
08/10/2011 FIREWALL/FIREBARRIER/FIRESTOP Partial Approval
08/09/2011 FIREWALL/FIREBARRIER/FIRESTOP Partial Approval
08/04/2011 FIREWALL/FIREBARRIER/FIRESTOP Partial Approval NEED TO CHECK ALL SHAFT PENETRATIONS IN MECHANICAL ROOMS BEFORE CARPET GOES IN (UNDER FLOOR)
07/29/2011 FIREWALL/FIREBARRIER/FIRESTOP Partial Approval
07/29/2011 FIREWALL/FIREBARRIER/FIRESTOP Partial Approval edge of slab west wall level 2, 6,7,8,9 ok. need to uncover insulation and scrim on levels 4,5 for inspection
07/27/2011 FIREWALL/FIREBARRIER/FIRESTOP Partial Approval NEED TO REMOVE FLOOR TILE AT ALL MECHANICAL ROOMS FOR INSPECTION OF F.S. AT ALL FLOOR DRAINS

LEVEL 2 REMOVE TILE AT STAIR 2. FIRESTOP NOT INSTALLED

STILL NEED TO SEE ABOVE CIELING LEVEL 9 RESTROOMS

LVL 2 WEST WALL CLOSURE OK
07/22/2011 FIREWALL/FIREBARRIER/FIRESTOP Partial Approval
07/21/2011 FIREWALL/FIREBARRIER/FIRESTOP Partial Approval STAIR 2, & LVL B3,B2,B1 ELEVATOR
07/20/2011 FIREWALL/FIREBARRIER/FIRESTOP Partial Approval
07/15/2011 FIREWALL/FIREBARRIER/FIRESTOP Partial Approval
07/13/2011 FIREWALL/FIREBARRIER/FIRESTOP Partial Approval
06/29/2011 FIREWALL/FIREBARRIER/FIRESTOP Partial Approval
06/27/2011 FIREWALL/FIREBARRIER/FIRESTOP Partial Approval
06/15/2011 FIREWALL/FIREBARRIER/FIRESTOP Partial Approval
06/10/2011 FIREWALL/FIREBARRIER/FIRESTOP Partial Approval
06/01/2011 FIREWALL/FIREBARRIER/FIRESTOP Partial Approval
05/26/2011 FIREWALL/FIREBARRIER/FIRESTOP Partial Approval
05/24/2011 FIREWALL/FIREBARRIER/FIRESTOP Partial Approval
05/17/2011 FIREWALL/FIREBARRIER/FIRESTOP Partial Approval
05/13/2011 FIREWALL/FIREBARRIER/FIRESTOP Partial Approval
05/10/2011 FIREWALL/FIREBARRIER/FIRESTOP Partial Approval LEVEL 3 LINE 11 NEED TO PULL ROCK OFF WALL
LEVEL 9 NEED REPAIR AT SHAFT
04/20/2011 FIREWALL/FIREBARRIER/FIRESTOP Partial Approval FIRESTOP LEVEL 5 FOR FLOOR PENETRATIONS OUTSIDE OF ELECTRIC ROOMS OK
04/19/2011 FIREWALL/FIREBARRIER/FIRESTOP Partial Approval NEED FIRESTOP FOR CONDUIT PENETRATIONS TO 4TH FLOOR SOFFIT
03/08/2011 FIREWALL/FIREBARRIER/FIRESTOP Partial Approval