Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/08/2011 | FRAMING | Approved | IVRS - Inspection :* | |
| 03/03/2011 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED ELECTRIC COMPLETE 2) ADD BANG PLATES THROUGHOUT 3) 1 1/4" FOR ROMEX, 1 1/2" FOR PLUMBING 4) NEED TO BOND GAS PIPING 5) J-BOX NEEDS TO BE ACCESSIBLE 6) BLOCK DUCT CANS 7) LAUNDRY P-TRAP NEEDS TO BE MINIMUM 18" FROM RECEPTOR BOX 8) NEED TO HARD PIPE DRYER VENT-NO FLEX PIPE ALLOWED IN WALLS COVERED WITH SHEETROCK 9) COMPLETE ALL FRAMING DETAILS TO PLANS 10) COMPLETE DUCT WORK AT TRANSITION |
|
| 02/22/2011 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 02/17/2011 | FRAMING | Not ready for Inspection | IVRS - Inspection :* |