Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T10CM03437
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/08/2011 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
08/23/2011 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* SEAL PENETRATION OF CONDUCTOR THROUGH STUCCO FOR AC REMOVE CONDUCTOR TO OUTLET FROM AC DISCONNECT SEAL HOLE IN SIDE OF DISCONNECT FOR UNUSED KNOCK OUT BUSING NEEDED FOR BACK OF AC DISCONNECT WATER TIE COVER NEEDED FOR OUTLET NEXT TO DOOR AT EXTERIOR PANEL UPGRADE PERMIT NEEDED MAXIMUM 15 AMP OVER CURRENT PROTECTION NEED FOR AC COMPRESSOR LABEL PANEL |