Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/25/2011 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 03/24/2011 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* 1) PROVIDE A SEDIMENT TRAP AT GAS LINE CONNECTION TO WATER HEATER 2) YOU CANNOT RE-USE ON OLD GAS FLEX CONNECTOR FOR A NEW WATER HEATER 3) PAINT EXPOSED PVC ON ROOF WITH LATEX PAINT. REPLACE ALL BROKEN BLOCKS USED FOR SUPPORT OF PVC. TERMINATE CONDENSATE TO WITHIN 6" OF THE GROUND 4) PROVIDE A ROOF JACK AT ELECTRIC CONDUIT 5) SLEEPERS UNDER A/C UNIT MUST SPAN THE ROOF JOISTS 6) WATER HEATER VENT ON ROOF IS LOOSE. PROVIDE SCREWS 7) MARK THE UNIT DATA PLATE FOR PROPER HEAT STRIP OR NO HEAT STRIP |