Permit: T10CM03289

Parcel: 133290330


Addresses:

8402 E VICKSBURG ST

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
05/24/2011 BUILDING - FINAL Approved IVRS - Inspection :*
11/29/2010 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) APPROVED FASTENERS NEEDED IN HOLDOWNS AND HANGERS
2) BEAM SPLICES TO BE OVER POSTS
3) ELECTRICAL WORK TO BE BROUGHT UP TO CODE OR SIGNED OFF BY LICENSED ELECTRICAL CONTRACTOR ON BUSINESS LETTER HEAD
4) LEDGER ATTACHMENT AT HOUSE VERIFIED OR EXPOSED AND LEDGER MATERIAL