Permit: T10CM03242

Parcel: 106041640

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T10CM03242

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
05/10/2011 PLUMBING - FINAL Approved IVRS - Inspection :*
05/04/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :* SEE NOTE #2 FROM 01-13-11
CAP OFF STOVE GAS VALVE
04/27/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
04/21/2011 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) POINT OF VENT MAY NOT BE BELOW THE WEIR OF THE TRAP
2) 1/4" PER SLOPE MAX 1002.4, ONLY ONE SLIP NUT ALLOWED AFTER P TRAP 1003.2
3) CHANGE OF DIRECTION OF TRAP ARM IS LIMITED PER UPC SECTION 1002.3
04/13/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) ALL PARTS SHALL BE LISTED (CODE APPROVED) DRAIN AND SUPPLIES
2) INSTALL A NEW TUB DRAIN AND OVER FLOW ON NEW TUB. FILL WITH WATER FOR TEST
04/06/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*