Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/24/2010 PLUMBING - FINAL Approved IVRS - Inspection :*
11/23/2010 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) PROVIDE WEATHER TIGHT FLASHING FOR 4 X 4'S ON ROOF AT TILE LEVEL
2) INSULATION ON ROOF PIPING FOR WATER SYSTEM TO BE PROPERLY SEALED AT SEAMS AND JOINTS AND BE PROTECTED FROM UV EXPOSURE PER MANUFACTURE
3) FOR OWNERS PROTECTION PROVIDE HOSE CAPS OR REMOVE HANDLES ON SOLAR PANEL DRAIN VALVES TO PREVENT ACCIDENTAL SCALDING
4) MANUFACTURE REQUIRES 25 AMP MAX BREAKER FOR CIRCUIT
11/17/2010 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*