Permit: T10CM03210

Parcel: 11504498A


Addresses:

850 E SPEEDWAY BL

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
11/29/2010 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
11/23/2010 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
1
11/22/2010 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
1) EXPOSE OVERHEAD GAS PIPING FOR INSPECTION. ALL PIPING IS TO BE SUPPORTED PER TABLE 3-2 2006 UPC
2) EACH WATER SUPPLIED APPLIANCE TO HAVE BACKFLOW PROTECTION
3) INDIRECT WASTE PIPING
4) 2 COMPS OF 3 COMP SINK TO BE DIRECTLY WASTED, GRATES & STRAINERS, APPROVED MATERIALS AND BACKFLOW CERTS
5) REQUIRE A TEST ON GAS SYSTEM-DO NOT TEST THRU ANSUL VALVE