Permit: T10CM03195

Parcel: 13333061A


Addresses:

9451 E ROSEWOOD ST

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
06/30/2011 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
06/22/2011 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ENGINEER APPROVAL FOR MISSING BEARING FOR CANTILEVIERD TRUSS
2) PLAN REVISION NEEDED OR EPOXY HOLDOWNS PER PLAN
3) ANCHOR BOLTS REQUIRED WITHIN 12" OF BOTTOM PLATE SEAMS
4) NAILS MISSING IN SHEARWALL NAILING PATTERN
5) NAIL PROTECT PLUMBING WITHIN 1 1/2" OF NAILING SURFACE
6) A34 MISSING AT JOIST TO PLATE CONNECTION
7) ALTERNATE GABLE END BRACE APPROVED BY ENGINEER
8) STOPPED INSPECTION TO MANY ITEMS TO LIST