Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T10CM03173

Parcel: 136241100


Addresses:

6725 E MARY DR

Inspection Status: Approved

Inspection History: ELECTRIC - SERVICE UPGRADE

Date Description Inspector Results Comments
11/23/2010 ELECTRIC - SERVICE UPGRADE Approved IVRS - Inspection :*
11/16/2010 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL ROOF JACK AT MAST PENETRATION
2) SERVICE CONDUCTORS NOT SIZED PROPERLY FOR 200 AMP SERVICE
3) GROUND RODS TO BE MINIMUM 6' APART
4) SEAL OPENING AT CABLE ENTRY BACK OF PANEL
5) PER GAS COMPANY REQUIREMENTS ALL ELECTRICAL DEVICES TO BE MINIMUM 36" FROM REGULATOR VENT