Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T10CM03070
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/30/2011 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
03/28/2011 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ALL RE-VENTING SHALL BE DONE 6" ABOVE UPPER FIXTURE 2) 2" TRAP ARMS ARE LIMITED TO 90 DEGREE CHANGE OF DIRECTION 3) P-10 IS INDIRECTLY WASTED, NO DIRECT CONNECTION ALLOWED 4) PREP SINK IS INDIRECTLY WASTED 5) WHY IS A DRAIN CONNECTION INSTALLED 6) OK TO INSULATE HW PIPING |