Permit: T10CM02931

Parcel: 141192000

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/14/2010 PLUMBING - FINAL Approved IVRS - Inspection :*
12/09/2010 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) PROVIDE APPROVED FLASHING AND INSTALL OF FLASHING
11/17/2010 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) SEE NOTE #5 AND PROVIDE FLASHING THAT IS USED FOR THIS STYLE ROOF TILE AND PIPE PENETRATIONS PROPERLY INSTALLED WITH FITTING CORRECTLY TOGETHER
11/05/2010 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE A SEDIMENT TRAP AT GAS ENTRY TO WATER HEATER
2) PROVIDE GFCI PROTECTION FOR NEW ELECTRICAL OUTLET
3) T & P DRAIN TO BE RIDGID PIPING (NO FLEXES) (3-5) SEAL PIPE TERMINATION THRU TO EXTERIOR
4) TUBING TO BE SUPPORTED AT 32" INCREMENTS PER INSTALLATION STANDARDS THRU OUT ENTIRE SYSTEM
5) PROVIDE APPROVED ROOF FLAHINGS FOR PIPE PENETRATIONS THRU ROOF
6) PROVIDE ACCESS TO ATTIC SPACE FOR TUBING INSPECTION