Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T10CM02740
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/10/2011 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
03/08/2011 | PLUMBING - ROUGH, SOIL | Denied | PROVIDE TEST ON ALL PIPING INCLUDING TEST TO ABOVE INLET AND OUTLET OF INTERCEPTOR. THERE CAN BE NO INCREASE THEN REDUCTION OF PIPE SIZE DOWNSTREAM OF THE INTERCEPTOR. REMOVE THE P-TRAP AT THE AREA DRAIN, IT WOULD NOT BE SELF SCOURING (BLOCKED BY SAND) |