Inspection History Details
Inspection Status: Cancelled
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/12/2010 | PLUMBING - FINAL | Cancelled | IVRS - RI canceled | |
| 10/12/2010 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 10/07/2010 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REMOVE TAPE ON WATER HEATER FLUE AT SINGLE WALLTO DBL WALL JOINT 2) A DRIP LEG/SEDIMENT TRAP IS NEEDED ON THE GAS FEED LINE. NEEDED ON DRYER GAS AS WELL 3) CAP OFF DRYER GAS LINE 4) REMOVE SUB PANEL COVER IN LAUNDRY FOR ELEVATION AT RE-INSPECT. IF THE HOUSE IS ON A 2 WIRE SYSTEM, OUTLETS MUST BE 2 PRONG OR GFI PROTECTED AND MARKED "NO GROUND" 5) PAINT ABS LAUNDRY VENT PIPE ON ROOF 6) INSTALL SMOKE DETECTOR IN HALLWAY OUTSIDE OF BEDROOMS 7) CLOTHES DRYER VENT DUCT MUST BE 4" WITH NO SCREWS AND VENT TO OUTSIDE 8) SEAL OPEN KNOCKOUTS IN MAIN PANEL 9) REMOVE STANDING WATER IN POOL |