Permit: T10CM02642
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/16/2010 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* 1) CORRECTIONS HAVE BEEN MADE |
|
| 09/23/2010 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) THHN WIRING CANNOT RUN BARE THRU ATTIC, PROVIDE CONDUIT OR RE-RUN WITH ROMEX 2) PROVIDE APPROVED FITTINGS FOR ELECTRICAL, PLUMBING FITTINGS NOT ALLOWED 3) THIS IS NOT A GROUND MOUNT UNIT, THIS IS A ROOF TOP UNIT. HAVE DESCRIPTION OF WORK CHANGED THRU CITY OF TUCSON PRIOR TO NEXT INSPECTION, FAILURE TO PROVIDE PROPER DESCRIPTION OF WORK WILL RESULT IN A REFEE 4) PROVIDE ROOF JACK AT ELECTRICAL PENETRATION |