Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
Permit Number - T10CM02626
Inspection Description - MECHANICAL - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/06/2011 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* | |
| 05/03/2011 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SECURE ANGLE IRON FRAME TO STRUCTURE 2) PROVIDE A SUN SHIELD OVER CANVAS CONNECTORS 3) MARK UNIT DATA PLATE W/PROPER HEAT STRIP INSTALLED & FUSE ACCORDINGLY 4) DO NOT USE WHITE WIRE FOR POWER TO A/C. OK TO WRAP WITH BLACK TAPE 5)PROVIDE A BUSHING IN DISCONNECT WHERE WIRES PASS THROUGH A/C CABINET |
|
| 04/28/2011 | MECHANICAL - FINAL | Not ready for Inspection | IVRS - Inspection :* |