Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/05/2011 | FRAMING | Approved | IVRS - Inspection :* | |
| 12/21/2010 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FLASH CONDUIT THRU ROOF 2) REVENT VANITY SINK 6" ABOVE FLOOD RIM OF SINK 3) PROVIDE APPROVED FITTINGS FOR VENTING OF PLUMBING AND USE CORRECT DIRECTION FOR VENTING 4) 2" VENT FOR STOOL THRU ROOF 5) PROPER SUPPORT FOR TUB RIM 6) 2 WAY CLEANOUT INSTALLED CORRECTLY BEFORE HOUSE 7) CONNECTION TO EXISTING TO BE APPROVED LONG RADIUS DRAINAGE FITTING FOR SEWER 8) ALL PEX TO BE SUPPORTED AT APPROVED DISTANCES AND APPROVED INTERVALS 9) PROVIDE LISTING FOR TUB SHOWER VALVE OR INSTALL APPROVED SHOWER VALVE |
|
| 12/20/2010 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 12/16/2010 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 12/15/2010 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED BY OWNER |
|
| 12/14/2010 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED TO REVISE PLANS TO SHOW TRUSSES IN PLACE OF 2 X 12 AND CONSULT WITH TRUSS ENGINEER TO ALLOW MECH UNIT ON ROOF |
|
| 12/10/2010 | FRAMING | Partial Approval | IVRS - Inspection :* 1) FRONT LIVING ROOM OK TO ROCK |
|
| 12/09/2010 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 12/06/2010 | FRAMING | Not ready for Inspection | IVRS - Inspection :* |