Permit: T10CM02615

Parcel: 12110007A


Addresses:

4748 E EDISON ST

Inspection Status: Approved

Inspection History: ELECTRIC - SERVICE UPGRADE

Date Description Inspector Results Comments
12/21/2010 ELECTRIC - SERVICE UPGRADE Approved IVRS - Inspection :*
10/22/2010 ELECTRIC - SERVICE UPGRADE Partial Approval IVRS - Inspection :*
1) NEED PANEL DIRECTORY
2) PROVIDE FUSES IN ELECTRIC DISCONNECT
3) PROVIDE THE REQUIRED GFI SERVICE RECEPT ON ROOF
4) DO NOT USE WHITE WIRE FOR POWER TO A/C UNIT. TAPE BOTH ENDS WITH BLACK TAPE
5) COMPLETELY COVER ALL PORTIONS OF CANVAS CONNECTORS FROM SUN DAMAGE
6) COMPLETELY SEAL AROUND SUPPLY AND RETURN ELBOWS ON ROOF
7) OUTDOOR RECEPTS TO BE GFI PROTECTED AND HAVE WEATHER PROOF COVERS
8) THIS IS A PARTIAL APPROVAL ON SERVICE UPGRADE PENDING TEP APPROVAL LOCATION OF SERVICE CONDUCTORS OVER POOL. WILL NEED NEW CLEARANCE IF SERVICE IS TO BE MOVED