Permit: T10CM02590

Parcel: 13325183B

Inspection Status: Approved

Inspection History: MECHANICAL - INTERMEDIATE

Permit Number - T10CM02590

Inspection Description - MECHANICAL - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
05/26/2011 MECHANICAL - INTERMEDIATE Approved IVRS - Inspection :*
05/12/2011 MECHANICAL - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
05/11/2011 MECHANICAL - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) ALL SECTIONS OF FIRE WRAP THAT CANNOT BE BANDED MSUT BE PINNED AS PER INSTALL INSTRUCTIONS
2) DO NOT USE FIBER GLASS INSULATION WITHIN 18" OF TOP OF HOOD
05/05/2011 MECHANICAL - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) 2ND LAYER OF FIRE WRAP PROGRESSING, BANDING TO BE 1 1/2" FROM EACH EDGE OF FIRE WRAP