Permit: T10CM02576

Parcel: 134160710


Addresses:

7456 E BEVERLY DR

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/05/2010 PLUMBING - FINAL Approved IVRS - Inspection :*
11/04/2010 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
10/25/2010 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) 1 1/2" MINIMUM CLEARANCE BETWEEN ROOF AND PIPING REQUIRED
2) 6" MINIMUM CLEARANCE REQUIRED FOR T & P TERMINATIONS ABOVE GRADE
3) MAKE TEMPERING VALVE ACCESSIBLE
4) A WATER HEATER SUPPORTED FROM THE GROUND SHALL REST ON LEVEL CONCRETE OR OTHER APPROVED BASE EXTENDING NOT LESS THAN 3" ABOVE GRADE UPC 508.3 (SMALL PAVERS ARE NOT ACCEPTABLE)
5) ELECTRICAL CONNECTIONS REQUIRE AN ELECTRICAL INSPECTION