Permit: T10CM02551

Parcel: 127101360


Addresses:

6270 E HAWTHORNE ST

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
10/26/2010 MECHANICAL - FINAL Approved IVRS - Inspection :*
1) CORRECTIONS HAVE BEEN MADE
10/20/2010 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) DO NOT TERMINATE T & P DRAINS ON WATER HEATER TO THE ROOF. T & P MUST SLOPE DOWNHILL TO DAYLIGHT OR USE THE ALTERNATE METHOD
2) PROVIDE MINIMUM 3 SCREWS IN ALL JOINTS OF WATER HEATER VENT CONNECTOR
3) BAROMETRIC DAMPER MUST BE ACCESSIBLE
4) SILICON CAULKING NOT APPROVED FOR PVC GLUE. PROVIDE PURPLE PRIMER PRIOR TO GLUING JOINTS
5) PROVIDE A ROOF JACK FOR EXHAUST AND DRAIN LINE ON ROOF. PAINT EXPOSED PVC WITH LATEX PAINT
10/13/2010 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PLEASE RESCHEDULE AN INSPECTION WHEN SOMEONE WILL BE HOME