Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/13/2010 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 10/07/2010 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NOTES 1,3,14 AND 6 FROM PREVIOUS |
|
| 10/05/2010 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BRACED WALL PANELS MUST REACH TOP/TOP PLATES 2) PROVIDE KING STUDS AT ALL WINDOW OPENINGS TO REACH TOP PLATE 3) PROVIDE SAFE ACCESS TO ROOF 4) OVER FRAME NOT PER PLAN SUMBIT AS BUILT OR BUILD TO PLAN. MISSING SLEEPERS, MISSING LU26 HANGERS 5) PLAN CALLS FOR S. SLIDER NORTH WALL 6) COMPLETE OSB INSTALLATION PER PLAN 7) MISSING SKY LIGHTS 8) STRAP 4 X 10 BEAM N.E. CORNER 9) RE-FRAME BRACED PANEL S.E. CORNER 48" PANEL |