Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - PRE SLAB
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/16/2010 | PLUMBING - PRE SLAB | Approved | IVRS - Inspection :* | |
| 09/14/2010 | PLUMBING - PRE SLAB | Not ready for Inspection | IVRS - Inspection :* 1) MAY NOT DUMP A DRAIN INTO A VENT 2) OK TO COVER WALL AT COLON HYDROTHERAPY SUBJECT TO APPROVED DETAIL |
|
| 09/07/2010 | PLUMBING - PRE SLAB | Not ready for Inspection | IVRS - Inspection :* 1) VENTS TO RISE VERTICALLY AT LEAST 6" ABOVE OVERFLOW BEFORE OFF SETTING HORIZONTAL 2) CLEANOUTS TO BE INSTALLED ABOVE THE FLOW LINE OF THE PIPE 3) PROVIDE DETAIL FOR COLON HYDROTHERAPY UNIT INCLUDE METHOD OF BACKFLOW PROTECTION 4) EXISTING CONDITIONS MAY BE MAINTAINED UNLESS THERE IS A DEFECT OR INSANITARY CONDITION. LEAKING PIPES COULD INDICATE FAILURE OR DEFECT |
|
| 08/31/2010 | PLUMBING - PRE SLAB | Not ready for Inspection | IVRS - Inspection :* 1) NO CHANGE AND PROVIDE TEST |