Permit: T10CM02162

Parcel: 106011070


Addresses:

3861 N 1ST AV

Inspection Status: Approved

Inspection History: PLUMBING - PRE SLAB

Date Description Inspector Results Comments
09/16/2010 PLUMBING - PRE SLAB Approved IVRS - Inspection :*
09/14/2010 PLUMBING - PRE SLAB Not ready for Inspection IVRS - Inspection :*
1) MAY NOT DUMP A DRAIN INTO A VENT
2) OK TO COVER WALL AT COLON HYDROTHERAPY SUBJECT TO APPROVED DETAIL
09/07/2010 PLUMBING - PRE SLAB Not ready for Inspection IVRS - Inspection :*
1) VENTS TO RISE VERTICALLY AT LEAST 6" ABOVE OVERFLOW BEFORE OFF SETTING HORIZONTAL
2) CLEANOUTS TO BE INSTALLED ABOVE THE FLOW LINE OF THE PIPE
3) PROVIDE DETAIL FOR COLON HYDROTHERAPY UNIT INCLUDE METHOD OF BACKFLOW PROTECTION
4) EXISTING CONDITIONS MAY BE MAINTAINED UNLESS THERE IS A DEFECT OR INSANITARY CONDITION. LEAKING PIPES COULD INDICATE FAILURE OR DEFECT
08/31/2010 PLUMBING - PRE SLAB Not ready for Inspection IVRS - Inspection :*
1) NO CHANGE AND PROVIDE TEST