Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/17/2010 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 12/09/2010 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) POLY TUBING REQUIRES SUPPORT WITH CLAMPS AT 32" MAX.-YOURS HAS NONE IN 30' 2) CONTINUED DENIED INSPECTIONS WILL RESULT IN REINSPECTION FEES |
|
| 11/24/2010 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE LADDER FOR ABOVE CEILING AND ROOF INSPECTIONS |
|
| 10/27/2010 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) SECURE EACH JOINT OF THE WATER HEATER VENT CONNECTOR WITH 3 GALV SHEET METAL SCREWS 2) KEEP PIPE INSULATION 6" FROM SINGLE WALL VENT CONNECTOR 3) STORAGE TANK REQUIRES PHYSICAL PROTECTION FROM DAMAGE IN GARAGE 4) SECURE PIPING 5) PROVIDE ACCESS TO ALL AREAS FOR INSPECTION |