Permit: T10CM02122

Parcel: 136141400

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
04/22/2011 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
04/20/2011 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
COIL STRAP BACK PATIO BEAM TO PLAN 6/S5.1 WITH MINIMUM (10) 8D NAIL INTO BEAM + (10) 8D NAILS INTO POST ON EACH SIDE OF BEAM
BRACE GABLE END TRUSS PER PLAN 5/S5.2
A35 NEEDED AT EACH BLOCK TO DOUBLE PLATE WHEN USING ALTERNATE ROTATED BLOCKING CONDITION PER 1/S5.2
RESTAPLE ROOF SHEATHING AT BIRD BOARDS AT SOUTH GARAGE WALL FOR SHINNERS
STAPLE VALLEY OF TOP SHEET ON WEST SIDE OF DORMER OVER FRONT DOOR