Permit: T10CM02120

Parcel: 136311450


Addresses:

9955 E SKYWARD WY

Inspection Status: Denied

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
04/28/2011 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
02/22/2011 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SUPPORT AND SECURE TUBING ON WALL
2) SUPPORT TUBING AND CONDUIT WITH A MINIMUM OF 1 1/2" ABOVE ROOF
3) INSULATE ALL PIPING ABOVE ROOF PER INSTALLATION INSTRUCTIONS WITH ADHESIVE AND UV PROTECTION. LEAVE NO EXPOSED PIPING
4) PROVIDE AN APPROVED ROOF FLASHING
5) PROVIDE APPROVED CONDUIT, NOT FLEX
6) PROVIDE A MEANS FOR WATER TO DRAIN OFF ROOF AROUND SUPPORTS
02/08/2011 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :* PROVIDE ACESS TO ROOF, HAVE CITY APPROVED PLAN ON SITE FOR THIS SYSTEM, NOTE: FAILURE TO BE READY AT INSPECTION TIME CAN RESULT IN REINSPECTION FEES AT FUTURE INSPECTIONS.