Inspection Status: Denied
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/28/2011 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 02/22/2011 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SUPPORT AND SECURE TUBING ON WALL 2) SUPPORT TUBING AND CONDUIT WITH A MINIMUM OF 1 1/2" ABOVE ROOF 3) INSULATE ALL PIPING ABOVE ROOF PER INSTALLATION INSTRUCTIONS WITH ADHESIVE AND UV PROTECTION. LEAVE NO EXPOSED PIPING 4) PROVIDE AN APPROVED ROOF FLASHING 5) PROVIDE APPROVED CONDUIT, NOT FLEX 6) PROVIDE A MEANS FOR WATER TO DRAIN OFF ROOF AROUND SUPPORTS |
|
| 02/08/2011 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* PROVIDE ACESS TO ROOF, HAVE CITY APPROVED PLAN ON SITE FOR THIS SYSTEM, NOTE: FAILURE TO BE READY AT INSPECTION TIME CAN RESULT IN REINSPECTION FEES AT FUTURE INSPECTIONS. |