Permit: T10CM02102

Parcel: 13316024P


Addresses:

6350 E GRANT RD

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
08/19/2011 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
07/01/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) EAST-SOUTHEAST SCREEN WALL FOOTING APPROX 25' OK TO POUR
06/22/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) 12 LIGHT POLE CASSION FOOTINGS NORTH-NE SIDES OK TO POUR
06/15/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) 10 CAISSION COLUMN FOOTINGS FOR PARKING CANOPIES-DETAIL #134, PAGE S4.02
05/16/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) FLAG POLE FOUNDATION-DETAIL #2, PAGE #1 (AWAITING SEPERATE PERMIT FOR THIS PROJECT) OK TO POUR FOOTING
05/10/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) 13 LIGHT POLE CAISSION FOOTINGS-OK TO POUR FOOTINGS (NORTH, NORTHEAST AND NORTHWEST CHECK GROUNDING SYSTEM WITH ELECTRIC INSPECTORS
04/26/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
04/21/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
SITE WALL FOOTINGS IN FRONT OF FUEL TANK DETAIL # 124 PAGE S4-02 OKAY TO POUR FOOTINGS
04/18/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
03/08/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) GL D.0/1.0 F5/C2 SHOWROOM CANOPY 7 F5/C2; A.1/3.0-11.0; 8 C2/F6, 11.0/A.-C.1 2 C2/F5; 8.0/B.5 1 C3/F8-OK TO POUR
02/23/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) SHOW ROOM CANOPY FOOTING: DETAIL #128, S4.02
02/17/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
02/16/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
02/09/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) WF2 FOOTINGS GL: 9.5/B.5-F.0; B.0/8.5-9.5 8.5/C.5-D OK TO POUR FOOTINGS
02/03/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
PARTIAL- COLUMN FOOTINGS 1 F8, 1F9 GL H.0/2, H4/2.
SOUTH/EAST SCREEN WALL-EAST WALL OF TRASH ENCLOSURE DETAIL #AS1.0, PAGE 3, OK TO POUR FOOTING.
02/02/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
CAR WASH FOOTING, GL Z4.5/ZB/5 - ZE.0 OK TO POUR
01/31/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) WALL FOOTINGS WF1 & WF7 GL: ZA.0/Z5.0-Z4.6; ZA.5/Z4.6-Z5.0; ZA.8/Z4.6-Z5.0; Z4.6/ZA.0-ZF.O; ZD.5/Z4.6-Z5.0; ZE.0/Z4.6-Z5.0 OK TO POUR PROGRESS AREAS
01/27/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) WALL FOOTINGS GL: ZA.0/Z1.0-Z3.0; ELEVATOR PIT; DETAILS #110, 110 PAGE S2.02 OK TO POUR PROGRESS AREAS
01/25/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) NON LOAD BEARING FOOTINGS AT GL: Z3.0/ZA.0-ZE.0 OK TO POUR
01/24/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) NON LOAD BEARING FOOTINGS AT GL: Z2.0-Z1.7/ZD.8; Z2.0/ZB.0-ZD.8; ZC.5/Z1.7-Z2.5; ZC.2/Z1.7-Z2.0 OK TO POUR FOOTINGS
01/20/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) GARAGE RAMP FOOTINGS GL: Z3.0-Z4.0/ZE.0; Z4.0/ZE.0-ZF.O; ZF.0/Z3.0-Z4.0-DETAILS #122, 123, 135 PAGE S2.02 OK TO POUR PROGRESS AREAS
01/18/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) FOOTINGS AT GL: Z1.0/ZA-ZF.0; ZF.0/Z1.0-Z1.5; Z1.5/ZE.0-ZF.0; ZE.0/Z1.5-Z1.7; Z2.0; Z2.0/ZE.0-ZF.O; ZE.0/Z2.0-Z2.5; Z2.5.0/ZE.0-ZF.0 ZF3.0-Z2.75.0/ZE.O OK TO POUR PROGRESS AREAS
01/14/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) FOOTING AND COLUMN FOOTING S.W. CORNER OF WAREHOUSE GL 5.0/I.0
01/12/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) FOOTINGS AT GL: .75/0-H.0/I.0; H.0/1.0-2.0; 2.0/G.0-COLUMN FOOTINGS: 3 F8, 2 F6, 1 C1/F6 OK TO POUR FOOTING
01/10/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) CONTINOUS FOOTING FOR CMU SITE WALL 181 L.F. ON EAST SIDE FROM ELECTRIC TRANSFORMER TO JUST SHORT OF SOUTH EAST ? CORNER AS PER DETAIL #129 ON SHEET #S-4.02 OK
01/07/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) COLUMN FOOTINGS AND FOOTINGS SOUTH WAREHOUSE
2) WALL GL: I-O/1.0-2.0; 2.0/H.75-I.0; DETAILS #A & B PAGE S2.01; 2 EACH F6 COLUMN FOOTINGS; 1 F9 COLUMN FOOTING-OK TO POUR PROGRESS AREA
12/28/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) COLUMN FOOTINGS (6) AT GL: Z1.0-ZA.0/ZF.0 (2) AT Z2.0/ZA.0/ZA.8 OK TO POUR
12/22/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) WALL FOOTING AT ZA.0-ZA.8/Z4.6; EAST SIDE OF STAIRWELL #1; COLUMN FOOTINGS AT Z1.7 (2 #F4); Z2.0 (3 F1)/ZD.8-ZC.2 OK TO POUR FOOTINGS
12/21/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) COLUMN FOOTINGS: GL: Z3.0-ZA, 3 F2, 3 F1; GL: Z2.0-ZF.0 1 F2-OK TO POUR PROGRESS AREAS
12/13/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) GL: Z5.0-ZA.0: 2 F/3, 1 F4; GL: Z4.0-ZA.0: 2 F/1, 1 F/2 FOOTINGS OK TO POUR PROGRESS AREAS
12/09/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) 7 COLUMN FOOTINGS: F1-F-2,F3 AT GL: ZD.0-ZF.0; Z4.0-Z5.0 OK TO POUR FOOTINGS