Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T10CM01995
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/08/2010 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 11/05/2010 | PLUMBING - FINAL | Cancelled | IVRS - RI canceled | |
| 07/21/2010 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSULATED SHEETMETAL SLEEVE ON FURNACE 2) VENT CONNECTOR INCREASER TO BE INSTALLED ON THE FURNACE OUTLET 3) USE 4" TO CONNECT TO FLUE 4) PROVIDE MINIMUM 3 SCREWS IN ALL JOINTS OF VENT CONNECTORS, NO TAPE 5) PROVIDE SEDIMENT TRAPS AT FURNACE AND WATER HEATER 6) T & P RELIEF DRAIN NOT CONNECTED. DO NOT USE FLEX COPPER TO CONNECT T & P 7) PROVIDE DBL WALL FLUE PIPING FROM CLOSET THRU THE ROOF WITH AN APPROVED CAP |