Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/22/2010 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 12/13/2010 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 11/01/2010 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) DWV WITH TEST OK 2) DOMESTIC WATER INSTALLED PER LETTER FROM RON MAZZEO, PROVIDE A CITY APPROVED PLAN REV. , ALSO NEED TO SEE CLOSET FLANGES |
|
| 10/28/2010 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) NEED TO POST SUITE NUMBER 2) WATER NOT SIZED PER PLAN 3) ACCESS REQUIRED FOR HAMMERS ARRESTORS 4) INSTALL BACKING AT MS 5) SWEEP REQUIRED ON HS TRAP ARM 6) SUPPORT HORIZONTAL ABS WITH ISOLATION FROM SHARP METAL 7) PROVIDE A WATER TEST ON DWV TO VENT TERMINATION |