Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T10CM01959
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/15/2010 | FRAMING | Approved | IVRS - Inspection :* | |
| 10/14/2010 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 10/13/2010 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999$ 1) FIRE STOP SOFFIT ABOVE KITCHEN SINK 2) FIRE STOP ? AT P TRAPS BETWEEN FLOORS 3) WIRES AGAINST GANG PLATE IN CEILING OF NORTH EAST BEDROOM AND HALLWAY 4) NO WATER IN DWV 5) PRESSURE NEEDED ON SOLAR LINES 6) BLOCK DUCT MINIMUM 3 SIDES FRONT LIVING ROOM 7) SUPPORT DUCT IN TRIANGLE NICHE CEILING |