Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T10CM01941

Parcel: 11307145A

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T10CM01941

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
09/09/2011 PLUMBING - INTERMEDIATE Approved
08/22/2011 PLUMBING - INTERMEDIATE Not ready for Inspection VENT FITTINGS BELOW FLOODRIM TO BE DRAINAGE TYPE
TEST GREASE TRAP
TEST ALL PIPING- EXPOSE ALL PIPE AND FITTINGS FOR INSPECTIONS
P-7 TRAP ARM MAY NOT CONNECT TO CLEANOUT UNDER HAND SINK
08/19/2011 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. AM INSP. REQUEST BY ROBERT W/SILVERADO PLUMBING
2. 11:30 AM INSP. W/RAIMEY FROM SILVERADO
3. STERILIZATION REQUIREMENT WAIVED BY RON BOOSE
4. P-7 DIRECT CONN IS NOT VENTED OR INSTALLED PER PLAN
5. P-9 EXISTING UTILITY SINK IS NOT CORRECTED WASTED
6. LAVATORY IS NOT PROPERLY VENTED, ALSO IT HAS PREVIOUSLY BEEN REPLACED W/A NON-ADA COMPLIANT FIXTURE.
7. DWV SYSTEM IS NOT UNDER TEST.
8. UNAPPROVED PRIMER HAS BEEN USED.
9. INDIRECT WASTE REQUIRES DRAINAGE FITTINGS AND COS
10. INTERCEPTOR VENT HAS NOT BEEN INSTALLED
11. P-4, P-8, P-12 AND P-13 FIXTURES SHOWN AS NEW ARE NOT PROPERLY CONNECTED.
12. CONDENSATE MAY NOT COMBINE W/ICE BIN DRAIN.
07/07/2011 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
01/13/2011 PLUMBING - INTERMEDIATE Partial Approval
12/27/2010 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*