Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/22/2010 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 08/10/2010 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) CUSTOMER WANTS TO TRANSFER AND CANCEL THIS PERMIT (T10EL01071)TO A REMODEL CONSTUCTION PERMIT SO TO HAVE TEMP POWER FOR WORK TO BE DONE (COMMENTS TRANSFERRED FROM T10EL01071) |
|
| 08/04/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : There is no access to the site.| 920* 1) CALLED AND SPOKE WITH CUSTOMER-LOCKED NO ACCESS 2) FINISH PREVIOUS ITEMS (COMMENTS TRANSFERRED FROM T10EL01071) |
|
| 05/10/2010 | ELECTRIC - FINAL | Denied | VRS - Inspection : See detailed listing on site.| 999* 1) EXPOSED WIRING IN CARPORT SHED 2) MISSING WATER HEATER COVER PLATE 3) MISSING HOOD-EXPOSED WIRING 4) KITCHEN RECEPTS TO BE GFCI PROTECTED 5) DISCONNECTING MEAN NEEDED FOR FURNACE 6) SMOKE DETECTORS NEEDED FOR HALL AND BEDROOMS, INSTALL AS PER INSTRUCTIONS 7) BATHROOM RECEPTS TO BE GFCI PROTECTED 8) FILL UNUSED OPENINGS IN PANEL 9) MISING DEAD FRONT COVER 10) MISSING GROUNDING ELECTRODE SYSTEM, GAS AND WATER BONDS 11) SECURE PANEL TO STRUCTURE (COMMENTS TRANSFERRED FROM T10EL01071) |