Permit: T10CM01921

Parcel: 130082800


Addresses:

1745 S CITATION AV

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
09/23/2010 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
08/19/2010 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE APPROVED T & P DRAIN TO APPROVED LOCATION
2) PRESSURE RELIEF TO GRAVITY DRAIN TO APPROVED LOCATION
3) SOLAR TUBING TO BE SUPPORTED AT CORRECT INTERVALS AT WATER HEATER AREA
4) SUPPORT SOLAR TUBING ON ROOF CORRECTLY ANDF REPAIR ALL HOLES FROM J-HOOKS WITH APPROVED ROOFING MATERIALS
5) PROPERLY IDENTIFY THE WATER HEATER CIRCUIT IN ELECTRICAL PANEL AND PROVIDE CORRECT ELECTRICAL BREAKER FOR THE WATER HEATER CIRCUIT