Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/26/2010 | PLUMBING - INTERMEDIATE | Approved | ||
| 09/24/2010 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MINIMUM 3" REQUIRED ABOVE CEILING FOR OUTSIDE APPLIANCES 2) PROVIDE CLEARANCE TO FILL CAP MINIMUM 6" 3) PROVIDE APPROVED COATING TO PROTECT PIPE INSULATION 4) CONTINUED DENIED INSPECTIONS WILL RESULT IN REINSPECTION FEE |
|
| 08/27/2010 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 07/16/2010 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) EXTERIOR STORAGE TANK REQUIRES PROPER SUPPORT AND PROTECTION FROM WEATHER 2) INSTALL INSULATION PER MANUFACTURES INSTRUCTIONS NEW INTERIOR WATER HEATER REQUIRES: 1) PROPER T & P RELIEF DRAIN TERMINATION PER CITY AMENDMENTS. SEE AND COMPLETE PETITION OF APPEAL FORM 2) NEW GAS FLEX PER MANUFACTURES REQUIREMENTS 3) SECURE VENT CONNECTOR AND PROVIDE PROPER TERMINATION; ALSO CLEARANCE FROM COMBUSTIBLES 4) REPLACE/REMOVE CORRODED NIPPLE ON COLD WATER CONNECTION |