Permit: T10CM01898

Parcel: 129021330


Addresses:

2736 E STRATFORD DR

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
10/26/2010 PLUMBING - INTERMEDIATE Approved
09/24/2010 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MINIMUM 3" REQUIRED ABOVE CEILING FOR OUTSIDE APPLIANCES
2) PROVIDE CLEARANCE TO FILL CAP MINIMUM 6"
3) PROVIDE APPROVED COATING TO PROTECT PIPE INSULATION
4) CONTINUED DENIED INSPECTIONS WILL RESULT IN REINSPECTION FEE
08/27/2010 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
07/16/2010 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) EXTERIOR STORAGE TANK REQUIRES PROPER SUPPORT AND PROTECTION FROM WEATHER
2) INSTALL INSULATION PER MANUFACTURES INSTRUCTIONS
NEW INTERIOR WATER HEATER REQUIRES:
1) PROPER T & P RELIEF DRAIN TERMINATION PER CITY AMENDMENTS. SEE AND COMPLETE PETITION OF APPEAL FORM
2) NEW GAS FLEX PER MANUFACTURES REQUIREMENTS
3) SECURE VENT CONNECTOR AND PROVIDE PROPER TERMINATION; ALSO CLEARANCE FROM COMBUSTIBLES
4) REPLACE/REMOVE CORRODED NIPPLE ON COLD WATER CONNECTION