Permit: T10CM01895

Parcel: 114467000

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T10CM01895

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
09/10/2010 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
1) SEAL ROOF FLASHINGS WITH TAR, SILICONE IS NOT APPROVED FOR THAT USE
07/21/2010 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) #2159
2) SECURE VENT WITH SCREWS AT EACH JOINT
3) FLEX IS NOT ALLOWED ON RELIEF DRAIN
4) SEDIMENT TRAP IS REQUIRED AT GAS CONNECTION
5) A GAS FLEX MAY NOT BE RE-USED
6) ALL TUBING ON ROOF REQUIRES SUPPORTS
7) PATCH NAIL HOLES