Permit: T10CM01886

Parcel: 11942006E

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
04/12/2011 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
04/11/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
04/08/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
04/07/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) 1ST LIFT ABOVE STEEL NORTH END
04/06/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
04/05/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* TOP OUT AS MARKED ON PLAN
04/04/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
04/01/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) AS MARKED ON 1/2 SET
03/31/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
03/30/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) EAST WALL ROOMS #312 AND 347 TO 20' 8"
03/29/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) TOP OUT AS MARKED ON 1/2 SHEET
03/28/2011 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
1) NOT READY PER CONTRACTOR
03/25/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) AS MARKED ON 1/2 SET SPECIAL INSPECTED
03/24/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) WEST WALL ROOM #329,343 & 344, NORTH WALL ROOM #311 & 312, WEST WALL #341 & 342 4TH LIFT
03/23/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
PARTIAL- AS MARKED ON PLAN.
03/22/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) AS MARKED ON 1/2 SET
03/21/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) AS MARKED ON PLAN
03/17/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) AS MARKED ON 1/2 SET
2) SPECIAL INSPECTED
03/16/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) AS MARKED ON PLAN-SPECIAL INSPECTED
03/15/2011 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
1) PER CONTRACTOR
03/14/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) SOUTH AND EAST WALL ROOMS #300 AND 302 TO 16' 8"
2) SPECIAL INSPECTED
03/11/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) AS MARKED ON 1/2 SET
03/10/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) AS MARKED ON 1/2 SET SPECIAL INSPECTED
03/04/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) AS MARKED ON 1/2 SET SPECIAL INSPECTED
03/03/2011 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
1) NOT READY PER CONTRACTOR
03/01/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) 1ST LIFT AND 2ND LIFT GABLE TOP OUT AS MARKED ON PLAN-SPECIAL INSPECTED
02/28/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) AS MARKED ON PLAN, SPECIAL INSPECTED
02/25/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) CMU WALLS AT 12'-16' 8"; #300 SOUTH WALL, 303 SOUTH WALL; 305 AND 307 WEST WALLS: CMU WALLS AT 16'-20' 8"-#311 WEST OK TO GROUT PROGRESS AREAS
02/24/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) CMU WALLS AT 4'-8" A.F.F.E.: NORTH WALLS OF #317,314,335,336,336A,337 AND 339, EAST WALL #336 AT 4'-8" OK TO GROUT
02/23/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) CMU WALLS: WEST WALLS #329, 333, 343, 344, FIRST LIFT AT 0'-4' 8", SOUTH WALL AT #325,326,342 AT 0'-4' 8", EAST WALLS #325 TO 332 0-4' 8", SOUTH WALL #338, GROUT ABOVE DBL DOORS (INCULDED)
02/22/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) CMU WALLS AT 18'-8" GL: 7/D-E; C-D/3-7; WALLS AT 16'-8": GL: C/1-3; AT 12'-8" GL: 1/C-M
02/17/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/16/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/15/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) CMU WALLS AT 12'-8"; GL: C.5-D/1.5-6.5 6.5/D-A; A/7-9, 8/A-B, B/8-8.5 CMU WALLS AT 4'-8"-GL: 2.5/L-O; 0-N.5/3.7.5 OK TO GROUT PROGRESS AREAS
02/11/2011 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
1) CONTRACTOR CANCELLED
02/08/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
PARTIAL AS MARKED ON 1/2 SET
02/01/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1ST LIFT AS MARKED ON PLAN
01/19/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) AS MARKED ON 1/2 SET SPECIAL INSPECTED
11/15/2010 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*