Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T10CM01801

Parcel: 11901076A


Addresses:

3346 S 6TH AV #100


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T10CM01801

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
03/08/2011 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
1) CONTRATOR PROVIDED PCDEQ AUTHORIZATION TO DISCHARGE. DWV WATER TEST THRU ROOF
03/07/2011 PLUMBING - ROUGH, SOIL Not ready for Inspection PROVIDE PROOF OF INSPECTION OF 6" SITE SEWER FOR REVISION 3 PAGE P.2, PROVIDE TEST FREE OF LEAKS AND NO WATER OR WET SOIL IN DITCHES, VENT FITTINGS BELOW FLOOD RIM OF FIXTURES TO BELONG RADIUS OR EQUAL. PROVIDE FULL SIZE 4" C/O FOR RESTROOM BRANCH.
03/04/2011 PLUMBING - ROUGH, SOIL Not ready for Inspection CANCELLED
02/03/2011 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
NOT READY PER CONTRACTOR