Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROOF DRAINS
Permit Number - T10CM01795
Inspection Description - PLUMBING - ROOF DRAINS
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/01/2011 | PLUMBING - ROOF DRAINS | Approved | SEE BUILD-OUT ACTIVITY T10CM03478 FOR FINAL INSPECTION INFORMATION | |
07/27/2011 | PLUMBING - ROOF DRAINS | Partial Approval | RD AT VORTEX FROM N SIDE. STILL NEED TO SEE COMPLETE TIE IN FROM WEST | |
07/20/2011 | PLUMBING - ROOF DRAINS | Partial Approval | PLACEMENT OF VORTEX SEDIMENT TRAP OK. OK TO BACKFILL WITH GRAVEL UP TO PIPE LEVEL. | |
05/11/2011 | PLUMBING - ROOF DRAINS | Partial Approval | IVRS - Inspection :* 1) 5 PSI AIR TEST ON RWL FROM 1ST L COL. E THRU ROOF OK 2) 5 PSI AIR TEST ON ORWLS, STACKS ANS L 9 ONLY OK. 1ST LEVEL CHANGES AND CORRECTIONS HAVE NOT BEEN MADE |
|
05/10/2011 | PLUMBING - ROOF DRAINS | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MAIN RWL TEST DROP FROM 4.7 TO 4.5 MINIMUM 5 PSI TEST REQUIRED 2) ORWL CORRECT HORIZONTAL AND HORIZONTAL CHANGE OF DIRECTION, ALSO OFF SET 3) PROVIDE RESTRAINTS AS REQUIRED |
|
05/06/2011 | PLUMBING - ROOF DRAINS | Not ready for Inspection | IVRS - Inspection :* 1) RWL INSPECTION REQUESTED BY LEERAY, NOT UNDER TEST. "BLOW OUT" 2) 45 DEGREE OFF SET SHOWN FOR ORWL AT STACK 7 3) SHOW CLEANOUTS ON PLAN REVISION 4) COMPLETE CHANGES PRIOR TO TESTING 5) SWEEPS OR 1/8" BENDS REQUIRED AT HORIZONTAL X HORIZONTAL AT ORWL FROM STAIRWELL CHASE |
|
04/18/2011 | PLUMBING - ROOF DRAINS | Not ready for Inspection | IVRS - Inspection :* | |
03/21/2011 | PLUMBING - ROOF DRAINS | Partial Approval | IVRS - Inspection :* |