Permit: T10CM01795

Parcel: 11717023D


Addresses:

88 E BROADWAY BL


Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T10CM01795

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
08/26/2011 REINFORCED MASONRY PRE-GROUT Approved
08/23/2011 REINFORCED MASONRY PRE-GROUT Partial Approval
08/17/2011 REINFORCED MASONRY PRE-GROUT Partial Approval
08/10/2011 REINFORCED MASONRY PRE-GROUT Partial Approval
08/09/2011 REINFORCED MASONRY PRE-GROUT Partial Approval
08/04/2011 REINFORCED MASONRY PRE-GROUT Partial Approval NEED FINAL TOP OF WALL WELDED SUPPORTS TO DECKS COMPLTED
07/29/2011 REINFORCED MASONRY PRE-GROUT Partial Approval GARAGE ENTRIES
07/27/2011 REINFORCED MASONRY PRE-GROUT Partial Approval
07/22/2011 REINFORCED MASONRY PRE-GROUT Partial Approval 12' AT ENTRY TO GARAGE
07/15/2011 REINFORCED MASONRY PRE-GROUT Partial Approval 8' AT GARAGE ENTRY
07/13/2011 REINFORCED MASONRY PRE-GROUT Partial Approval
06/27/2011 REINFORCED MASONRY PRE-GROUT Partial Approval
06/24/2011 REINFORCED MASONRY PRE-GROUT Partial Approval
06/15/2011 REINFORCED MASONRY PRE-GROUT Partial Approval
06/01/2011 REINFORCED MASONRY PRE-GROUT Partial Approval
05/24/2011 REINFORCED MASONRY PRE-GROUT Partial Approval
05/17/2011 REINFORCED MASONRY PRE-GROUT Partial Approval
05/13/2011 REINFORCED MASONRY PRE-GROUT Partial Approval
05/10/2011 REINFORCED MASONRY PRE-GROUT Partial Approval
05/04/2011 REINFORCED MASONRY PRE-GROUT Partial Approval NEED TO PULL SHEET ROCK OFF LINE 11 LEVEL 3. STEEL FLANGES AT TOP OF MASONRY WALL ARE INCORRECT SIZE, DO NOT COVER UNTIL REPAIRS MADE AND INSPECTIONS APPROVED.
04/29/2011 REINFORCED MASONRY PRE-GROUT Partial Approval
04/28/2011 REINFORCED MASONRY PRE-GROUT Partial Approval SHAFT CAP AT J/16 TOPPED OUT
04/27/2011 REINFORCED MASONRY PRE-GROUT Partial Approval
04/22/2011 REINFORCED MASONRY PRE-GROUT Partial Approval
04/20/2011 REINFORCED MASONRY PRE-GROUT Partial Approval
04/19/2011 REINFORCED MASONRY PRE-GROUT Partial Approval
04/11/2011 REINFORCED MASONRY PRE-GROUT Partial Approval LEVEL 3 WEST AND EAST AREA ON 2,3,5
04/05/2011 REINFORCED MASONRY PRE-GROUT Partial Approval
04/01/2011 REINFORCED MASONRY PRE-GROUT Partial Approval LEVELS 2,3,4 PROGRESS SOUTH SIDE OK
03/31/2011 REINFORCED MASONRY PRE-GROUT Partial Approval
03/30/2011 REINFORCED MASONRY PRE-GROUT Partial Approval SOUTH SIDE LEVELS 2-4 PROGRESS OK
03/25/2011 REINFORCED MASONRY PRE-GROUT Partial Approval SOUTH SIDE FLOORS 1,2,3 MECHANICAL ROOMS AND CRASH WALL PROGRESS OK
03/24/2011 REINFORCED MASONRY PRE-GROUT Partial Approval
03/15/2011 REINFORCED MASONRY PRE-GROUT Partial Approval ISSUES WITH SPLICE LAP TOO SHORT ON CRASH WALL LINE 14 LEVEL 1. NEED TO HAVE ENGINEER RESOLVE, AND NEED TO SPEAK TO SPECIAL INSPECTOR WHO WAS ON DUTY.
03/11/2011 REINFORCED MASONRY PRE-GROUT Partial Approval 3RD FLOOR 4'. ONE DOWELL MISSING LINE E, OK PER ENGINEER.
03/10/2011 REINFORCED MASONRY PRE-GROUT Partial Approval
03/04/2011 REINFORCED MASONRY PRE-GROUT Partial Approval
03/03/2011 REINFORCED MASONRY PRE-GROUT Partial Approval
03/03/2011 REINFORCED MASONRY PRE-GROUT Partial Approval PROGRESS ON B2, 1 AND 2
02/25/2011 REINFORCED MASONRY PRE-GROUT Partial Approval ALL PROGRESS ALL LEVELS OK
02/23/2011 REINFORCED MASONRY PRE-GROUT Partial Approval
02/08/2011 REINFORCED MASONRY PRE-GROUT Partial Approval BASEMENT LEVELS OK TO GROUT
02/07/2011 REINFORCED MASONRY PRE-GROUT Partial Approval B-3 and level 2 progress good
02/04/2011 REINFORCED MASONRY PRE-GROUT Partial Approval
02/02/2011 REINFORCED MASONRY PRE-GROUT Partial Approval
01/25/2011 REINFORCED MASONRY PRE-GROUT Partial Approval
01/19/2011 REINFORCED MASONRY PRE-GROUT Partial Approval CONTINUED WORK ON PLAZA LEVEL
01/12/2011 REINFORCED MASONRY PRE-GROUT Partial Approval
01/07/2011 REINFORCED MASONRY PRE-GROUT Partial Approval
01/05/2011 REINFORCED MASONRY PRE-GROUT Partial Approval
01/03/2011 REINFORCED MASONRY PRE-GROUT Partial Approval NORTH SIDE LEVEL 1 4' TO 8' OK TO GROUT
12/29/2010 REINFORCED MASONRY PRE-GROUT Partial Approval REMOVAL OF FACE BLOCK LEVEL B2 STAIR 2 COMPLETED FOR INSPECTION. VERIFICATION OF BOND BEAM AND ANCHORS ACCEPTED FOR B1,B2,B3 STAIR WALLS
12/28/2010 REINFORCED MASONRY PRE-GROUT Partial Approval MEETING HELD TO DISCUSS BOND BEAMS LEVELS B1-B3 AT STAIR 2 COVERED WITHOUT INSPECTION AND TO GO OVER WHERE WALLS SHALL BE SOLID GROUTED (OR PERLITE FILLED) FOR FIRE RATINGS.
12/27/2010 REINFORCED MASONRY PRE-GROUT Partial Approval NEED TO INSTALL VERTS LEVEL B2 AT RAMP WALL
12/17/2010 REINFORCED MASONRY PRE-GROUT Partial Approval
12/16/2010 REINFORCED MASONRY PRE-GROUT Partial Approval
12/10/2010 REINFORCED MASONRY PRE-GROUT Partial Approval
12/09/2010 REINFORCED MASONRY PRE-GROUT Partial Approval
12/09/2010 REINFORCED MASONRY PRE-GROUT Partial Approval