Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T10CM01765
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/29/2011 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
06/24/2011 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* 1) OK TO MOVE IN FURNITURE AND EQUIPMENT, NOT FOR SEEING PATIENTS |
|
06/21/2011 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) NEED MECHANICAL AND FIRE FINALS 2) VERTICAL GRAB BARS IN ADA RESTROOM AND SHOWER 3) RESTROOM SIGNAGE FOR 3 RESTROOMS |