Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/05/2010 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 11/03/2010 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) H2.5 RAFTERS AT EAST WALL 2) MOVE PEX FROM LIGHT IN LAUNDRY |
|
| 10/21/2010 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEE #2 FROM ABOVE |
|
| 10/15/2010 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. MISSED 1 ROW OF ROOF NAILING ON PLYWOOD NEXT TO S.E. SKYLIGHT 2. H 2.5 ALL RAFTERS IN HOUSE AND ON REAR PORCH. 3. LAG FRONT PORCH LEDGERS PER PLAN 4. CLIP, STRAP, OR BLOCK HANGING EXISTING GRAY RAFTER AT WEST SIDE OF REAR PORCH. 5. NAIL WALL O3B OUTSIDE OF S.E. SHOWER |