Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
07/28/2011 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
05/17/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) DUMPSTER AND MECH ENCLOSURE
04/18/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
04/14/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
04/13/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) ROOM 108, 108.1 (NORTH WALL) 8'-10 #107.4, 120-122 NORTH AND EAST WALLS 8'-12' OK TO GROUT PROGRESS AREAS
04/12/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) NORTH, EAST AND SOUTH WALL TO 8' ROOMS 107, 122 AND 120
2) ROOM 108, 108.1 TO 8'
04/11/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
04/08/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
04/07/2011 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
1) CANCELLED PER CONTRACTOR
04/06/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) INSTALL WELD PLATES
2) ? CONTROL JOINT SLIPS
3) NO LAP WITHIN 8' OF CONTROL JOINT
04/05/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*1)RM 107 N&E WALL 5TH LIFT EXCEPT FOR BINDELS SO WALL TO 16' 2)HAVC ROOM EXT WALLS 4TH LIFT 3)WEST ENTRY 3RD LIFT
04/04/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
04/01/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) INTERIOR SOUTH ENTRANCE WALL 12'
2) EAST CENTER SECTION WALL AND NORTH WALL
3) MECH ROOM TO 12'
4) WEST ENTRANCE TO 8'
03/30/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) NORTH, EAST AND WEST INTERIOR SECTION 3RD LIFT SOUTH WALL TO 8'
03/29/2011 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
1) NOT READY PER CONTRACTOR
03/28/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) WEST SECTION PERIMETER TOP OUT
2) INTERIOR NORTH/SOUTH WALLS 2ND LIFT
3) MECH ROOM AND WEST ENTRY TO 4'
03/24/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) WEST SECTION EXCEPT ENTRY TOP OUT
2) INTERIOR EAST TO WEST WALL AND COLUMNS TO 4'
03/22/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) WEST SECTION PERIMETER 3RD LIFT
2) NORTH 1/2 OF WEST INTERIOR WALL
3) WEST INTERIOR WALL OF EAST SECTION 1ST LIFT
03/21/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) EAST & WEST PERIMETER WALLS 2ND LIFT TO 8' CENTER SECTION TO 4'
2) TERRACON SPECIAL INSPECTED
03/16/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) WEST AND EAST SECTION PERIMETER 1ST LIFT SPECIAL INSPECTED
02/28/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
02/23/2011 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*