Permit: T10CM01671

Parcel: 141386840

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T10CM01671

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
08/25/2010 FRAMING Approved IVRS - Inspection :*
08/24/2010 FRAMING Not ready for Inspection IVRS - Inspection :*
08/23/2010 FRAMING Partial Approval IVRS - Inspection :*
1) REMOVE MESH STAPLES AT HOME RUNS
2) FHA STRAP TOP PLATES AT GAS MAIN FOR OVERBORE
3) NEED LONG SWEEP 90 DEGREE IN DRYER DUCT FOR OVERSPAN