Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/01/2010 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 09/16/2010 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) RECEIVED PETITION OF APPEAL FOR T & P 2) SEE NOTE #5 ABOVE AND COMPLY 3) WEATHER PROOF ENCLOSURE TO BE WEATHER PROOF, EXPOSED EDGES TO BE PROTECTED FROM WEATHER DAMAGE 4) ELECTRIC CONDUIT THAT WAS DISTURBED TO BE PROPERLY SUPPORTED ON ROOF 5) PROVIDE ROOFING PRODUCTS TO SECURE SUPPORTS TO ROOF |
|
| 07/23/2010 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) NEW GAS WATER HEATER REQUIRES GRAVITY DRAIN TO DAYLIGHT OF TEMPERATURE/PRESSURE RELIEF VALVE OR INSTALLATION PER PETITION OF APPEAL LEFT ON SITE TO BE SIGNED BY OWNER 2) VENT CONNECTOR PIPING TO BE INSTALLED WITH OVERLAP LOWER INTO UPPER WITH FASTENERS AT ALL VENT JOINTS 3) PROVIDE CORRECT PAD OR LISTING FOR LIGHT EQUIPMENT PAD AND WEATHER PROOF ENCLOSURE FOR STORAGE TANK AND PUMP ASSEMBLY 4) PROVIDE EXTENSION LADDER ON SITE FOR ALL INSPECTIONS FOR ACCESS TO ROOF TOP 5) PROVIDE INSULATION FOR POTABLE PIPING EXPOSED TO FREEZING. INSULATION TO E PROPERLY SEALED AND PROTECTED FROM SUN LIGHT DAMAGE. USE APPROVED MEANS FROM MANUFACTURER 6) ROOF FLASHINGS TO BE NON METALIC TO COPPER CONTACT 7) NO ACCESS TO ROOF TOP 8) LABEL PUMP CIRCUIT IN ELECTRICAL PANEL 9) LIST IS NOT COMPLETE |