Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
Permit Number - T10CM01537
Inspection Description - EXCAVATION/LAYOUT REBAR & ZON
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/25/2011 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :* | |
| 12/08/2010 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE STUCCO CERT 2) DDO APPROVED 7/26/10 3) EXPOSE FOOTERS FOR VERIFICATION OF DEPTH-ALL STRUCTURES GARAGE: 1) 5/8" FIRESTOP REQUIRED FOR ROOF TOP EAST WALL. 1/2" OSB AND STUCCO OK (EXTERIOR) 2) AT LEAST ONE 12/2 GFCI CIRCUIT REQUIRED IN GARAGE. ELECTRICAL EXISTING NOT TO CODE 3) INSTALL 20 MIN SELF CLOSING SERVICE DOOR GARAGE TO AZ ROOM AZ ROOM: 1) REQUIRES HEAT 2) EXPOSE POINTS OF CONNECTION BOTH BEARING WALLS TO RAFTERS 3) BEDROOM WINDOWS LACK REQUIRED EMERGENCY EGRESS IN EXISTING BEDROOMS TO PUBLIC WAY DUE TO GARAGE ADDITION ATTACHED STORAGE: 1) DROP INTO PANEL REQUIRES 8' CLEARANCE STORAGE ROOF LINE STORAGE: 1) OMIT ELECTRICAL NOT TO CODE 2) FIRE RATE OVER HANG WITHIN 36" PROPERTY LINE |