Permit: T10CM01527

Parcel: 141311010

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T10CM01527

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
07/08/2010 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
07/07/2010 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ROOF NOT NAILED ABOVE PANTRY
2) REAR GARAGE OSB NOT NAILED
3) SHEAR TRANSFER PANEL NOT NAILED ON PATIO
4) H2.5 GABLE END TRUSS TO PATIO GLUE LAM
5) RSP4 PATIO COLUMN STUDS AT BOTTOM
6) STRAP NON CABIN TIED TOP PLATES AT FRONT BEDROOM AND ENTRY DOOR
7) CORRECT ANGLED WALL TOP PLATE INSIDE ENTRY DOOR
07/02/2010 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO APPROVED PLANS VISIBLE ON SITE
2) NO ROOF ACCESS
07/01/2010 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*